14 plus
- Source & Measured DC Voltage, Resistance, Thermocouple Temperature Detector, Resistance Temperature Detector.
- Can use temperature detector with high Accuracy of ±0.2°C
- It can be calibrated without open the cover of the calibrator
- The Backlight and the power supply can be shut Off automatically
- Display : 6 Digits LCD with white backlight LED
- DC Voltage : 0 – 50mV/500mV
- Resolution : 1µV / 10µV, Accuracy : ±0.02%
- Resistance : 0.00Ω to 550Ω
- Resolution : 0.01Ω, Accuracy : ±0.05%
- R Type Thermocouple : 0°C to 1767°C
- Resolution : 1°C, Accuracy : ±1.5°C
- S Type Thermocouple : 0°C to 1767°C
- Resolution : 1°C, Accuracy : ±1.5°C
- K Type Thermocouple : -100.0°C to 1372°C
- Resolution : 0.1°C, Accuracy : ±0.8°C
- E Type Thermocouple : -50.0°C to 850°C
- Resolution : 0.1°C, Accuracy : ±0.9°C
- J Type Thermocouple : -60.0°C to 1120°C
- Resolution : 0.1°C, Accuracy : ±0.7°C
- T type Thermocouple : -100.0°C to 400°C
- Resolution : 0.1°C, Accuracy : ±0.7°C
- N Type Thermocouple : -200.0°C to 1300.0°C
- Resolution : 0.1°C, Accuracy : ±0.9°C
- B Type Thermocouple : 600.0°C to 1820°C
- Resolution : 1°C, Accuracy : 1.4°C
- L –Type Thermocouple : -60°C to 900°C
- Resolution : 0.1°C, Accuracy : 0.5°C
- U Type Thermocouple : -100°C to 600°C
- Resolution : 0.1°C, Accuracy : ±0.5°C
- PT-100-385 : -200°C to 800°C
- Resolution : 0.1°C, Accuracy : ±0.5°C
- PT-200-385 : -200°C to 630°C
- Resolution : 0.1°C, Accuracy : ±0.22°C
- PT-500-385 : -200°C to 630°C
- Resolution : 0.1°C, Accuracy : ±0.3°C
- PT-1000-385 : -200°C to 630°C
- Resolution : 0.1°C, Accuracy : ±0.4°C
- Cu10 Sensor : -100°C to 260°C
- Resolution : 0.1°C, Accuracy : ±2°C
- Cu50 Sensor : -50°C to 150°C
- Resolution : 0.1°C, Accuracy : ±0.5°C
- Continuity : ≤50Ω Sound
- Resolution : 0.01Ω, Accuracy : ±0.02%
- Source & Measured DC Voltage, Resistance, Thermocouple Temperature Detector, Resistance Temperature Detector.
- Can use temperature detector with high Accuracy of ±0.2°C
- It can be calibrated without open the cover of the calibrator
- The Backlight and the power supply can be shut Off automatically
- Display : 6 Digits LCD with white backlight LED
- DC Voltage : 0 – 50mV/500mV
- Resolution : 1µV / 10µV, Accuracy : ±0.02%
- Resistance : 0.00Ω to 550Ω
- Resolution : 0.01Ω, Accuracy : ±0.05%
- R Type Thermocouple : 0°C to 1767°C
- Resolution : 1°C, Accuracy : ±1.5°C
- S Type Thermocouple : 0°C to 1767°C
- Resolution : 1°C, Accuracy : ±1.5°C
- K Type Thermocouple : -100.0°C to 1372°C
- Resolution : 0.1°C, Accuracy : ±0.8°C
- E Type Thermocouple : -50.0°C to 850°C
- Resolution : 0.1°C, Accuracy : ±0.9°C
- J Type Thermocouple : -60.0°C to 1120°C
- Resolution : 0.1°C, Accuracy : ±0.7°C
- T type Thermocouple : -100.0°C to 400°C
- Resolution : 0.1°C, Accuracy : ±0.7°C
- N Type Thermocouple : -200.0°C to 1300.0°C
- Resolution : 0.1°C, Accuracy : ±0.9°C
- B Type Thermocouple : 600.0°C to 1820°C
- Resolution : 1°C, Accuracy : 1.4°C
- L –Type Thermocouple : -60°C to 900°C
- Resolution : 0.1°C, Accuracy : 0.5°C
- U Type Thermocouple : -100°C to 600°C
- Resolution : 0.1°C, Accuracy : ±0.5°C
- PT-100-385 : -200°C to 800°C
- Resolution : 0.1°C, Accuracy : ±0.5°C
- PT-200-385 : -200°C to 630°C
- Resolution : 0.1°C, Accuracy : ±0.22°C
- PT-500-385 : -200°C to 630°C
- Resolution : 0.1°C, Accuracy : ±0.3°C
- PT-1000-385 : -200°C to 630°C
- Resolution : 0.1°C, Accuracy : ±0.4°C
- Cu10 Sensor : -100°C to 260°C
- Resolution : 0.1°C, Accuracy : ±2°C
- Cu50 Sensor : -50°C to 150°C
- Resolution : 0.1°C, Accuracy : ±0.5°C
- Continuity : ≤50Ω Sound
- Resolution : 0.01Ω, Accuracy : ±0.02%